pulverized metallic (gray cast iron) aggregate,
factory mixed with oxidizing agents. It is field
mixed with portland cement, sand, and water and
applied in two coats with stiff bristle brushes,
wedging particles into, and filling, pores and
apertures.
**************************************************************************
**************************************************************************
NOTE: On the drawings, show:
1. Location and extent
of metallic waterproofing.
If not shown, designate
surfaces to be waterproofed
in a paragraph entitled
"Surfaces to be
Waterproofed," inserted
in Part 3.
2. Details of pipe and conduit penetrations through
treated walls or floor.
3. Continuous groove or cove at juncture of floor
and walls and at juncture of floor and columns 38 mm
1 1/2 inches in cross section, cut into floor, walls
and columns. Indicate that groove is to be filled
with metallic oxide waterproofing mortar.
4. Details of expansion and control joints.
**************************************************************************
PART 1
GENERAL
1.1
REFERENCES
**************************************************************************
NOTE: Issue (date) of references included in
provided by the latest guide specification. Use of
SpecsIntact automated reference checking is
recommended for projects based on older guide
specifications.
**************************************************************************
The publications listed below form a part of this specification to the
extent referenced. The publications are referred to within the text by the
basic designation only.
ASTM INTERNATIONAL (ASTM)
ASTM C 144
(2003) Aggregate for Masonry Mortar
ASTM C 150
(2004a) Portland Cement
ASTM C 33
(2003) Concrete Aggregates
1.2
SUBMITTALS
**************************************************************************
NOTE: Submittals must be limited to those necessary
for adequate quality control. The importance of an
item in the project should be one of the primary
SECTION 07161
Page 4