3.1.1.2
Wall
[Cabinet] [vanity] [_____] to be wall mounted shall utilize minimum 13 mm
1/2 inch thick lumber or panel product hanging strips, minimum 60 mm 2-1/2
inch width; securely attached to the wall side of the cabinet back, both
top and bottom.
3.1.2
Countertops
Countertops shall be installed in locations as indicated on the drawings.
Countertops shall be fastened to supporting casework structure with
mechanical fasteners, hidden from view. All joints formed by the
countertop or countertop splash and adjacent wall surfaces shall be filled
with a clear silicone caulk. Loose [back] [side] splashes shall be adhered
to both the countertop surface perimeter and the adjacent wall surface with
adhesives appropriate for the type of materials to be adhered. Joints
between the countertop surface and splash shall be filled with clear
silicone caulk in a smooth consistent concave bead. Bead size shall be the
minimum necessary to fill the joint and any surrounding voids or cracks.
3.1.3
Hardware
Casework hardware shall be installed in types and locations as indicated on
the drawings. Where fully concealed European-style hinges are specified to
be used with particleboard or fiberboard doors, the use of plastic or
synthetic insertion dowels shall be used to receive 5 mm 3/16 inch
"Euroscrews". The use of wood screws without insertion dowels is
prohibited.
3.1.4
Doors, Drawers and Removable Panels
The fitting of doors, drawers and removable panels shall be accomplished
within target fitting tolerances for gaps and flushness in accordance with
AWI Qual Stds [premium] [custom] grade requirements.
3.1.5
Plumbing Fixtures
Sinks, sink hardware, and other plumbing fixtures shall be installed in
locations as indicated on the drawings and in accordance with [Section 15400
PLUMBING, GENERAL PURPOSE] [_____].
3.1.6
Glass
Glass and glazing shall be installed in the casework using methods and
materials specified in Section 08800 GLAZING in locations as indicated on
the drawings.
-- End of Section --
SECTION 06410A
Page 24