All interior and exterior surfaces: [HPDL Grade CLS] [Thermoset
Decorative Overlay (melamine)].
f. Countertops and Splashes.
All exposed and semi-exposed surfaces: HPDL Grade HGS
g. Tolerances
Flushness, flatness, and joint tolerances of laminated surfaces
shall meet the AWI Qual Stds [premium] [custom] grade requirements.
2.12.8
Finishing
2.12.8.1
Filling
No fasteners shall be exposed on laminated surfaces. All nails, screws,
and other fasteners in non-laminated cabinet components shall be
countersunk and the holes filled with wood filler consistent in color with
the wood species.
2.12.8.2
Sanding
All surfaces requiring coatings shall be prepared by sanding with a grit
and in a manner that scratches will not show in the final system.
2.12.8.3
Coatings
Types, method of application and location of casework finishes shall be in
accordance with the finish schedule, drawings and Section 09900 PAINTS AND
COATINGS. All cabinet reveals shall be painted.
PART 3
EXECUTION
3.1
INSTALLATION
Installation shall comply with applicable requirements for AWI Qual Stds
[premium] [custom] quality standards. Countertops and fabricated
assemblies shall be installed level, plumb, and true to line, in locations
shown on the drawings. Cabinets and other laminate clad casework
assemblies shall be attached and anchored securely to the floor and walls
with mechanical fasteners that are appropriate for the wall and floor
construction.
3.1.1
Anchoring Systems
3.1.1.1
Floor
[Base cabinets] [_____] shall utilize a floor anchoring system [as detailed
on the drawings]. Anchoring and mechanical fasteners shall not be visible
from the finished side of the casework assembly. [Cabinet] [_____]
assemblies shall be attached to anchored bases without visible fasteners
[as indicated in the drawings]. Where assembly abutts a wall surface,
anchoring shall include a minimum 13 mm 1/2 inch thick lumber or panel
product hanging strip, minimum 60 mm 2-1/2 inch width; securely attached to
the top of the wall side of the cabinet back.
SECTION 06410A