2.2
LONGSPAN STEEL JOISTS
[Longspan steel joists] [and] [deep longspan steel joists] shall conform to
SJI Specs & Tables, [LH-Series] [DLH-Series]. Joists designated [LH] [and]
[DLH] shall be designed to support the loads given in the applicable
standard load tables of SJI Specs & Tables.
2.3
JOIST GIRDERS
Joist girders shall conform to SJI Specs & Tables.
2.4
ACCESSORIES AND FITTINGS
Accessories and fittings, including end supports and bridging, shall be in
accordance with the standard specifications under which the members were
designed.
2.5
SHOP PAINTING
**************************************************************************
NOTE: The requirements of the paragraph will be
coordinated with the requirements of Section 09900
PAINTING, GENERAL. In crawl spaces and other high
humidity areas where greater protection than that
provided by a primer paint is required and the
joists or girders will not be finish painted, the
paragraph will be revised to require that the joists
or girders be shop painted with an asphalt-base type
paint.
**************************************************************************
Joists [, joist girders] and accessories shall be shop painted with a
rust-inhibiting primer paint. For joists [and joist girders] which will be
finish painted under Section 09900 PAINTING, GENERAL, the primer paint
shall be limited to a primer which is compatible with the specified finish
paint.
PART 3
EXECUTION
3.1
ERECTION
Installation of joists [and joist girders] shall be in accordance with the
standard specification under which the member was produced. Joists [and
joist girders] shall be handled in a manner to avoid damage. Damaged
joists [and joist girders] shall be removed from the site, except when
field repair is approved and such repairs are satisfactorily made in
accordance with the manufacturer's recommendations. Joists [and joist
girders] shall be accurately set, and end anchorage shall be in accordance
with the standard specification under which the joists [and joist girders]
were produced. For spans over 12 m 40 ft through 18 m 60 ft one row of
bridging nearest midspan shall be bolted diagonal bridging; for spans over
18 m 60 ft bolted diagonal bridging shall be used instead of welded
horizontal bridging. Joist bridging and anchoring shall be secured in
place prior to the application of any construction loads. Any temporary
loads shall be distributed so that the carrying capacity of any joist is
not exceeded. Loads shall not be applied to bridging during construction
or in the completed work. Abraded, corroded, and field welded areas shall
be cleaned and touched up with the same type of paint used in the shop
painting.