e. Block Gaps:
Gaps between adjacent blocks shall not exceed
3 mm
1/8 inches.
3.12
PROTECTION OF WORK
Work shall be protected against damage from subsequent operations.
Disturbed or displaced blocks shall be removed and replaced to conform to
all requirements of this section. Damaged material shall not be
incorporated into the wall. Upon completion of wall erection, the
Contractor shall clean the wall face to remove any loose soil deposits or
stains.
-- End of Section --
SECTION 02832
Page 27