Management System (RMS) are: "AE" for
Architect-Engineer; "DO" for District Office
(Engineering Division or other organization in the
District Office); "AO" for Area Office; "RO" for
Resident Office; and "PO" for Project Office. Codes
following the "G" typically are not used for Navy
projects.
Submittal items not designated with a "G" are
considered as being for information only for Army
projects and for Contractor Quality Control approval
for Navy projects.
**************************************************************************
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for [Contractor Quality Control
approval.] [information only. When used, a designation following the "G"
designation identifies the office that will review the submittal for the
Government.] The following shall be submitted in accordance with Section
01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Shop Drawings[; G][; G, [_____]]
Fabrication and installation drawings. The shop drawings shall
include all items described under paragraph SEGMENTAL RETAINING
WALL DESIGN.If approved by the Contracting Officer, shop drawings
may consist of marked up contract drawings showing exact
dimensions for the blocks supplied, required coping, and other
minor revisions.
SD-03 Product Data
Components and Equipment
Descriptive technical data on the blocks, wall caps, masonry
adhesive, reinforcement, geotextile filter materials and equipment
to be used. The submittal shall include all material properties
specified under PART 2 PRODUCTS. The submittal shall also include
a copy of any standard manufacturer's warranties for the products.
Supplier Qualifications
Manufacturer's Representative
Documentation showing that the installer and supplier meet the
qualifications listed.
Soil Testing[; G][; G, [_____]]
Reinforcement Testing[; G][; G, [_____]]
Testing data specific to the blocks and reinforcement to be
supplied.
a. The shear strength between blocks shall be established in
accordance with NCMA TR127.
b. The connection strength between the blocks and the
reinforcement shall be established in accordance with ASTM D 6638.
SECTION 02832
Page 8