SD-03 Product Data
Forced Entry Resistant Components
Manufacturer's descriptive data and finish samples. The forced
entry resistant door lock functions, for selection by the
Contracting Officer. Airflow calculations for louvers.
Installation
maintenance instructions.
Components
Lists including schedule of components to be incorporated in the
work with manufacturer's model or catalog numbers, specification
designated, [fire ratings,] [sound transmission coefficient
ratings,] [insulation "U" value,] and number of items provided.
Listing of similar products that have been satisfactorily in use
for two years or more, including name of purchasers, locations of
installations, dates of installations, and service organizations.
SD-07 Certificates
Forced Entry Resistant Components[; G][; G, [_____]]
Manufacturer's certificates attesting that components conform to
the requirements on drawings and in specifications. Testing
reports from independent testing laboratories indicating
conformance to regulatory requirements shall be included. Fire
rated doors may be furnished with certificate in lieu of a label.
Certificate shall indicate compliance with the requirements for
doors of the type and fire rating class. Manufacturer shall
drawings will provide the specified degree of forced entry
1.4
STANDARD PRODUCTS
**************************************************************************
NOTE: The manuals listed below contain information
on the forced entry tactic.
TM 5-853-1/AFMAN 32-1071, Vol. 1, Security
Engineering - Project Development
TM 5-853-2/AFMAN 32-1071, Vol. 2, Security
Engineering - Concept Design
TM 5-853-3/AFMAN 32-1071, Vol. 3, Security
Engineering - Final Design
These manuals are marked "For Official Use Only",
and they may be ordered by Department of the Army
agencies from the U.S. Army Publications
Distribution Center, 2800 Eastern Blvd., Baltimore,
SECTION 11025
Page 9