ceiling] framing] in accordance with the specifications contained in [UL
Fire Resist Dir for the Design Number(s) indicated], [or] [GA 600 for the
File Number(s) indicated]. Joints of fire-rated gypsum board enclosures
shall be closed and sealed in accordance with UL test requirements or GA
requirements. Penetrations through rated partitions and ceilings shall be
sealed tight in accordance with tested systems. Fire ratings shall be as
indicated.
3.7
PATCHING
Patch surface defects in gypsum board to a smooth, uniform appearance,
ready to receive finish as specified. [Remove predecorated gypsum board
which cannot be restored to like-new condition. Provide new predecorated
gypsum board.]
3.8
The shaft wall system shall be installed in accordance with the system
manufacturer's published instructions. Bucks, anchors, blocking and other
items placed in or behind shaft wall framing shall be coordinated with
electrical and mechanical work. Fireproofing materials which are damaged
or removed during shaft wall construction shall be patched or replaced.
-- End of Section --
SECTION 09250
Page 19