USACE / NAVFAC / AFCESA
UFGS-08120N (September 1999)
------------------------------
Preparing Activity: NAVFAC
Replacing without revision
NFGS of same number and date
UNIFIED FACILITIES GUIDE SPECIFICATIONS
References are in agreement with UMRL dated 23 June 2005
**************************************************************************
SECTION 08120
ALUMINUM DOORS AND FRAMES
09/99
**************************************************************************
NOTE: This guide specification covers the
requirements for aluminum doors and frames intended
for use principally as main entrance and vestibule
doors, and for prominent interior doors from lobbies
and similar spaces in buildings of public access
where appearance is a major factor.
Comments and suggestions on this guide specification
are welcome and should be directed to the technical
proponent of the specification. A listing of
technical proponents, including their organization
designation and telephone number, is on the Internet.
Recommended changes to a UFGS should be submitted as
a Criteria Change Request (CCR).
Use of electronic communication is encouraged.
Brackets are used in the text to indicate designer
choices or locations where text must be supplied by
the designer.
**************************************************************************
**************************************************************************
NOTE: On the drawings, show:
1. Size of door openings; thickness, swing and
travel of doors; whether flush, paneled, glazed, or
louvered; width of stiles and rails
2. Elevations of each door and frame type, at 1:50
1/4 inch scale
3. Details of head, jamb, sill, mullions, and
transom sections; key sections to door frame
elevations; type and spacing of anchors
4. Type and thickness of glazing required and
method of glazing
5.
Details of weatherstripping for exterior doors
SECTION 08120
Page 3