section. Install card near point of access to roof, or where indicated.
Send a photostatic paper copy to [LANTNAVFACENGCOM, Code 1613, 1510 Gilbert
Street, Norfolk, VA 23511-2699] [NORTHNAVFACENGCOM, Code 103A, 10
Industrial Highway, Mail Stop #82, Lester, PA 19113-2090] [PACNAVFACENGCOM,
Code 102, Pearl Harbor, HI 96860-7300] [SOUTHNAVFACENGCOM, Code 0535, P.O.
Box 190010, North Charleston, SC 29419-9010] [SOUTHWESTNAVFACENGCOM, Code
133SB, 1220 Pacific Highway, San Diego, CA 92132-5190].
3.8
SCHEDULE
Some metric measurements in this section are based on mathematical
conversion of English unit measurements, and not on metric measurement
commonly agreed to by the manufacturers or other parties. The English and
metric units for the measurements shown are as follows:
PRODUCTS
ENGLISH UNITS
METRIC UNITS
a.
Sheet Aluminum
0.040 inch
1.0 mm
b.
Panels
12 inches
300 mm
- vertical legs
2 inches
50 mm
- stiffening ribs
4 inches
100 mm
c.
Screws
No. 14
0.242 mm
No. 12
0.216 mm
d.
Bolts
1/4 inch
6 mm
e.
Studs
3/16 inch
5 mm
f.
Fasteners
1/2 inch
13 mm
One inch
25 mm
g.
Rivets
1/16 inch
5 mm
1/8 inch
3 mm
3.9
FORM ONE
SECTION 07612N
Page 23