entire specification will be edited for appropriate
paragraphs and definitions, reference specimens,
acceptance/rejection standards, and other associated
data.
**************************************************************************
1.1
REFERENCES
**************************************************************************
NOTE: Issue (date) of references included in
provided by the latest guide specification. Use of
SpecsIntact automated reference checking is
recommended for projects based on older guide
specifications.
**************************************************************************
The publications listed below form a part of this specification to the
extent referenced. The publications are referred to within the text by the
basic designation only.
AMERICAN SOCIETY FOR NONDESTRUCTIVE TESTING (ASNT)
ASNT Q&A Bk C
(1994) Question and Answer Book C:
Ultrasonic Testing Method; (Supplement to
Recommended Practice SNT-TC-1A)
ASNT RP SNT-TC-1A
(2001) Recommended Practice
AMERICAN WELDING SOCIETY (AWS)
AWS D1.1/D1.1M
(2004) Structural Welding Code - Steel
ASTM INTERNATIONAL (ASTM)
ASTM E 165
(2002) Liquid Penetrant Examination
ASTM E 709
(2001) Magnetic Particle Examination
1.2
DEFINITIONS
1.2.1
A Scan
Method of data presentation on a cathode ray tube using rectangular
coordinates in which a horizontal base line indicates elapsed time when
reading from left to right. A vertical deflection in the base line
indicates reflect signal amplitude.
1.2.2
Acoustically Similar Material
Material the same as that to be inspected; or
another material
proven to
have acoustical velocity within plus or minus
3 percent and an
within plus or minus 0.001 dB/mm 0.25 dB/inch
of the inspected
material for
the inspection frequency and wave mode, using
the same mode as
that to be
used for inspection.
1.2.3
Amplitude
When referring to an indication in A scan presentation, amplitude is the
SECTION 05092A
Page 5