3.4
PROTECTION OF WORK
Precast units shall be protected against damage from subsequent operations.
3.5
DEFECTIVE WORK
Precast concrete units damaged during erection shall be repaired as soon
after occurrence as possible or replaced, as directed, using approved
procedures. All repairs to precast concrete units shall match the adjacent
surfaces in color and texture and shall be as approved. Unless otherwise
MNL-117].
-- End of Section --
SECTION 03413A
Page 12