Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are for [Contractor Quality Control
approval.] [information only. When used, a designation following the "G"
designation identifies the office that will review the submittal for the
Government.] The following shall be submitted in accordance with Section
01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Waterstops[; G][; G, [_____]]
Shop drawings and fabrication drawings provided by the
manufacturer or prepared by the Contractor.
SD-03 Product Data
Preformed Expansion Joint Filler
Sealant
Waterstops
Manufacturer's literature, including safety data sheets, for
preformed fillers and the lubricants used in their installation;
field-molded sealants and primers (when required by sealant
manufacturer); preformed compression seals; and waterstops.
Manufacturer's recommended instructions for installing preformed
fillers, field-molded sealants; preformed compression seals; and
waterstops; and for splicing non-metallic waterstops.
SD-04 Samples
Lubricant for Preformed Compression Seals
Specimens identified to indicate the manufacturer, type of
material, size and quantity of material, and shipment or lot
represented. Each sample shall be a piece not less than 3 m 9 ft
of 25 mm 1 inch nominal width or wider seal or a piece not less
than 4 m 12 ft of compression seal less than 25 mm 1 inch nominal
width. One L quart of lubricant shall be provided.
Field-Molded Type
Four liters One gallon of field-molded sealant and one L quart
of primer (when primer is recommended by the sealant manufacturer)
identified to indicate manufacturer, type of material, quantity,
and shipment or lot represented.
Specimens identified to indicate manufacturer, type of material,
size, quantity of material, and shipment or lot represented. Each
sample shall be a piece not less than 300 mm 12 inch long cut from
each 61 m 200 ft of finished waterstop furnished, but not less
than a total of 1 m 4 ft of each type, size, and lot furnished.
One splice sample of each size and type for every 50 splices made
in the factory and every 10 splices made at the job site. The
splice samples shall be made using straight run pieces with the
splice located at the mid-length of the sample and finished as
required for the installed waterstop. The total length of each
splice shall be not less than 300 mm 12 inches long.
SECTION 03150A
Page 6