approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Formwork[; G][; G, [_____]]
Drawings showing details of formwork, including dimensions of
fiber voids, joints, supports, studding and shoring, and sequence
of form and shoring removal.
SD-03 Product Data
Design
used in the design.
Form Materials
Manufacturer's data including literature describing form
materials, accessories, and form releasing agents.
Form Releasing Agents
Manufacturer's recommendation on method and rate of application
of form releasing agents.
SD-04 Samples
Fiber Voids[; G][; G, [_____]]
One sample unit of fiber voids prior to installation of the
voids.
SD-07 Certificates
Fiber Voids
Certificates attesting that fiber voids conform to the specified
requirements.
1.3
DESIGN
Formwork shall be designed in accordance with methodology of ACI 347R for
anticipated loads, lateral pressures, and stresses. Forms shall be capable
of producing a surface which meets the requirements of the class of finish
specified in Section 03300A CAST-IN-PLACE STRUCTURAL CONCRETE. Forms shall
be capable of withstanding the pressures resulting from placement and
vibration of concrete.
1.4
STORAGE AND HANDLING
Fiber voids shall be stored above ground level in a dry location. Fiber
voids shall be kept dry until installed and overlaid with concrete.
SECTION 03100A