complex and can be reviewed through the Contractor's
submittal is sufficiently important or complex in
context of the project.
For submittals requiring Government approval on Army
projects, a code of up to three characters within
the submittal tags may be used following the "G"
designation to indicate the approving authority.
Codes for Army projects using the Resident
Management System (RMS) are: "AE" for
Architect-Engineer; "DO" for District Office
(Engineering Division or other organization in the
District Office); "AO" for Area Office; "RO" for
Resident Office; and "PO" for Project Office. Codes
following the "G" typically are not used for Navy
projects.
Submittal items not designated with a "G" are
considered as being for information only for Army
projects and for Contractor Quality Control approval
for Navy projects.
**************************************************************************
Government approval is required for submittals with a "G" designation;
submittals not having a "G" designation are [for Contractor Quality Control
approval.][for information only. When used, a designation following the
"G" designation identifies the office that will review the submittal for
the Government.] The following shall be submitted in accordance with
Section 01330 SUBMITTAL PROCEDURES:
SD-02 Shop Drawings
Block Installation[; G][; G, [_____]]
Geotextile Installation[; G][; G, [_____]]
Drawings shall be submitted that show details of the ACB and
Geotextile Installation. The details shall show the block layout
patterns in relation to the feature alignment, anticipated
locations of cast-in-place concrete joints, mattress junction
details, soil anchors, and proposed installation methods for void
filling materials.
SD-03 Product Data
Articulating Concrete Block[; G][; G, [_____]]
Geotextile[; G][; G, [_____]]
Descriptive technical data shall be submitted on the blocks,
cables, cable fittings, soil anchors, and geotextile. The
submittal shall include all material properties specified under
paragraph PRODUCTS. Catalog cuts, technical data sheets, or test
data shall be submitted showing that the products meet the
specifications. The submittal shall also include a copy of any
standard manufacturer's warranties for the products.
Anchors[; G][; G, [_____]]
The Contractor shall submit calculations for the anchor pullout
SECTION 02382
Page 6